Learn / Data Acquisition & Analysis / Measurement fundamentals: ADC resolution, sensor specs and uncertainty
L2 · Practitioner

Measurement fundamentals: ADC resolution, sensor specs and uncertainty

Every logged number is an estimate. Know how ADC resolution and sampling limit what you can see, how to read a sensor data sheet, and how to put an honest uncertainty on a result – including whether a setup change really made a difference.

Measurement fundamentals: ADC resolution, sensor specs and uncertainty: L1 Foundation explanation

Measured value ≠ true value. The chain is: physical process (true value) → sensor → signal conditioning → analogue-to-digital conversion → stored number (measured value). Every step adds error. The best you can do is estimate a range within which the true value most probably lies.

ADC resolution. An ADC with nn bits divides its input range into 2n2^n steps. A 12-bit input on 0–5.5 V has 5500/4096≈1.345500/4096 \approx 1.34 mV per step. If a 100 mm linear potentiometer outputs 0–5 V, it uses about 3720 of those steps, so one step ≈ 0.027 mm. Wire the same pot to a 0–15 V input (15000/4096≈3.6615000/4096 \approx 3.66 mV per step) and only ~1365 steps are used: resolution degrades to ~0.073 mm. Match the sensor's output span to the input range.

Why that matters: damper velocity is a derivative. At 100 Hz, one step of 0.073 mm between samples equals 7.3 mm/s – already inside the low-speed damper range (typically 0–25/50 mm/s). Your velocity histogram would be quantised into useless bins. Note the trap: raising the sampling rate makes the velocity quantum larger (Δv=Δx⋅fs\Delta v = \Delta x \cdot f_s), so the fix is more ADC bits, a matched input range or a differentiation stencil spanning several samples – not more Hz.

Sensor data sheet vocabulary: transfer function (output vs input), sensitivity (slope, e.g., mV/g), offset (output at zero input), measurement range, tolerance/uncertainty, non-linearity, hysteresis, noise and resolution.

Key formulas

ADC resolution
ΔVLSB=Vrange2n\Delta V_{LSB} = \frac{V_{range}}{2^{n}}
VrangeV_{range}
input range (V)
n
number of bits
ΔVLSB\Delta V_{LSB}
voltage per step
Quantisation of a derivative
Δvmin=ΔxLSB fs\Delta v_{min} = \Delta x_{LSB}\, f_s
ΔxLSB\Delta x_{LSB}
displacement resolution (mm)
fsf_s
sampling rate (Hz)
Δvmin\Delta v_{min}
smallest non-zero velocity step (mm/s)
Standard uncertainty of a mean
σxˉ=σn\sigma_{\bar{x}} = \frac{\sigma}{\sqrt{n}}
σ\sigma
standard deviation of samples
n
number of independent samples
Significance of a difference between two runs
Δtˉ>t0.975,νσA2nA+σB2nB\Delta\bar{t} > t_{0.975,\nu}\sqrt{\frac{\sigma_A^2}{n_A} + \frac{\sigma_B^2}{n_B}}
Δtˉ\Delta\bar{t}
difference of mean lap times (s)
σA,B\sigma_{A,B}
lap-time scatter of each run (s)
nA,Bn_{A,B}
number of clean laps
t0.975,νt_{0.975,\nu}
Student-t factor for 95 % (≈2 for many laps, 2.3 for 5 + 5 laps)
Laps per run needed to resolve a gain
n≥2(2σΔ)2n \ge 2\left(\frac{2\sigma}{\Delta}\right)^2
n
clean laps per run
σ\sigma
lap-time scatter (s)
Δ\Delta
expected lap-time gain (s)

Trackside takeaways

  • Match the sensor output span to the logger input range to use the full ADC resolution.

  • Derivatives amplify quantisation: displacement resolution × sampling rate = velocity step.

  • Calibrate away systematic errors; averaging only reduces random ones.

  • Consecutive samples are not independent – compute statistics per corner or per lap.

  • Before declaring a setup change better, check the gain exceeds about twice the standard error of the difference (Student-t ≈ 2.3 for five-lap runs).

  • Run A-B-A to cancel drift; small gains need corner-level metrics, not 50-lap runs.

On your car

Tyre-pressure gauge bias between team and tyre supplier is a classic systematic error – with mandatory minimum pressures in many GT series, a 0.05 bar gauge error can mean a penalty.

Check yourself

Question 1 / 5L2 · Practitioner

A 0–5 V, 75 mm damper pot is connected to a 12-bit, 0–15 V logger input and sampled at 200 Hz. Roughly what is the smallest non-zero damper velocity step?

Further reading
  • Segers – Analysis Techniques for Racecar Data Acquisition — §19.1–19.3 Introduction; A/D conversion; Sensor Selection and Application
  • Segers – Analysis Techniques for Racecar Data Acquisition — §19.4 Measurement Uncertainty · roll ratio uncertainty example